| TECHNICAL
SPECS
RADCO Test Reports
Mechanical Property Tests on Oriented Strand Board Facings (PDF, 257 kB)
Calculation Manual Index (PDF, 973 kB)
Axial Load Tests on Sandwich Panels (PDF, 760 kB)
Transverse Load Tests on Sandwich
Panels (PDF, 949 kB)
Properties Tests on Expandable Polystyrene
Foam Board (PDF, 228 kB)
Racking Shear Tests on Sandwich Panels (PDF, 1.10 MB)
Room Fire Test per UBC 26-3 on Sandwich Panels (PDF, 3.08 MB)
Adhesive
All R-Tight® panels are manufactured
using Morton Thiokol (now a division of Rohm & Haas) Mor-Ad
M-series one-part, non-volatile urethane adhesives. The adhesive
is applied together with an aqueous spray (water is the second component)
according to manufacturers recommended loading ratios. The adhesive
is applied to panel components, which are then laminated at 7-10
psi in custom-designed air pod presses. Techical specifications
for the Mor-Ad ahdesive can be found in National Evaluation Report
NER-451, Reissued September 1, 1997.
Oriented Strand Board
Oriented strand board (OSB) is manufactured by Weyerhaeuser
or Huber woods products. The standard 7/16" thickness is used
for all R-Tight® panels. Huber Blue OSB panels have
a Class C (III) flame spread rating as discussed in the HUD/FHA
Manual of Acceptance Practices, Section 405-8 to the Minimum Property
Standards. Weyerhaeuser OSB "Structurewood" was evaluated
using ASTM E 84 Tunnel Furnace Test Methods with Series T-4388 through
T-4390. Structurewood is Class C, as certified by Hardwood Plywood
Manufacturer's Association.
Drywall
R-Tight® panels are typically manufactured
with GypsumTM Cameo® Veneer Board Plaster
Base which has Flame Spread 15 and Smoke Developed 0 Surface Burning
Characteristics per ASTM 84 or CAN/ULC-S102.
Expanded Polystyrene (EPS)
All R-Tight® panels are manufactured
with Carpenter Insulation Company or Polar Industries EPS 1.0 pcf
density Type I foam blanks. Carpenter Insulation Company EPS was
evaluated by ASTM Test D1622 for density. Tests showed a Thermal
Resistance of 4.17 at 40 degrees F for 1" thick EPS. Dimensional
Stability was evaluated using ASTM Test D2126 to show a maximum
of 2% change. Underwriters Laboratories Inc.® UL
Test 723 or ASTM E 84 showed 5" thick or 6" thick Carpenter
Insulation Company EPS had Flame Spread 15, Smoke Developed 250.Carpenter
Insulation Company EPS is UL Listed.
|